manager@kiaev6.org (915) 212-77133

Kia EV6: Specification

Specification

Motor and Reduction Gear

Item Specification
70 kw (Front wheel) 160 kw (Rear wheel)
Motor Type Permanent magnet synchronous motor
(IPMSM)
Permanent magnet synchronous motor
(IPMSM)
Reduction gear ratio 10.65 10.65
Maximum power (kW) 70 160
Maximum torque (Nm) 255 350
Maximum rotational speed (rpm) 15,000 17,900
Cooling method Oil cooling Oil cooling

Oil Temperature Sensor

Item Specification
Sensor Type NTC thermistor
Operating Voltage (V) 4.75 - 5.25
Max current (mA) 100
Response time Test medium : Coolant MAX. 5 sec
Oil temperature [°C (°F)] -40 to 150 (-40 to 302)

Oil Temperature Sensor Table

Temperature [°C (°F)] Resistance (kΩ)
Minimum Nomal Maximum
-40 (-40) 41.74 48.14 54.54
-30 (-22) 23.54 26.74 29.94
-20 (-4) 14.13 15.48 16.83
-10 (14) 8.393 9.308 10.223
0 (32) 5.281 5.790 6.299
10 (50) 3.422 3.714 4.007
20 (68) 2.310 2.450 2.590
30 (86) 1.554 1.658 1.762
40 (104) 1.084 1.148 1.212
50 (122) 0.7729 0.8126 0.8524
60 (140) 0.5615 0.5865 0.6115
70 (158) 0.4154 0.4311 0.4469
80 (176) 0.3122 0.3222 0.3322
90 (194) 0.2382 0.2446 0.2510
100 (212) 0.1844 0.1884 0.1924
110 (230) 0.1451 0.1471 0.1491
120 (248) 0.1139 0.1163 0.1187
130 (266) 0.0908 0.0930 0.0953
140 (284) 0.0731 0.0752 0.0773
150 (302) 0.0594 0.0614 0.0634

    Previous pageHigh Voltage Shut-off Procedures

    High Voltage Shut-off Procedures     • When working on high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of under ...

    PREV

    Next pageTightening Torque

    Tightening Torque Front Under Cover Item N·m kgf·m lb·ft lb·in Front under cover bolts 7.8 - 11.8 0.8 - 1.2 5.8 - 8.7 ...

    NEXT
    Other information:

    Kia EV6 (CV) 2022– Workshop Manual: C Pillar Garnish
    Removal 1.Remove the C-pillar garnish (A).     Clip position : Installation 1.Install in the reverse order of removal. ...

    Kia EV6 (CV) 2022– Workshop Manual: Description and Operation
    Description Electric Power Conversion System Description • The electric power conversion is a system that converts power (AC/DC ↔ DC/AC) according to its use. • It converts more than one of the voltage, current frequency or phrase without loss of power. Electric Power Conversion Syste ...